GalvoClosedLoopScanner10Kpps: Unterschied zwischen den Versionen
Aus Hackerspace Ffm
(→E-Bay) |
|||
(Eine dazwischenliegende Version desselben Benutzers wird nicht angezeigt) | |||
Zeile 1: | Zeile 1: | ||
− | Budget Laser Scanner Galvo Set ILDA Closed Loop 12 Kpps | + | Budget Laser Scanner Galvo Set ILDA Closed Loop 12 Kpps from E-Bay. |
+ | <embedvideo service="youtube">https://youtu.be/mtmszeuKH9A</embedvideo> | ||
== E-Bay == | == E-Bay == | ||
+ | The original informations form the seller: | ||
[[Datei:12kpps_scanner_ilda_closed_loop_02.JPG|200px|thumb|left|Gelieferte Elektronik]] | [[Datei:12kpps_scanner_ilda_closed_loop_02.JPG|200px|thumb|left|Gelieferte Elektronik]] | ||
Zeile 15: | Zeile 17: | ||
* Mirror dimensions WxL: 7mm*11mm*0.6mm(wide wave-length) | * Mirror dimensions WxL: 7mm*11mm*0.6mm(wide wave-length) | ||
* Board size:7.4cm(long)*5.0cm(wide)*2.5cm(high) | * Board size:7.4cm(long)*5.0cm(wide)*2.5cm(high) | ||
− | + | <br> | |
The Scanner was measured by an independent source and confirmed by the factory with PANGOLIN QM2000 card. Running at the desired output speed. Using the standard ILDA test pattern. Laboratory power supply at +/-15VDC,room temperature. Windows PC with Pangolin,12/30k ILDA test-frame full size. 7x11x0.6mm mirror was used during measuring period. The galvo is fixed in the standard mounts on an aluminium base plate, no forced cooling. | The Scanner was measured by an independent source and confirmed by the factory with PANGOLIN QM2000 card. Running at the desired output speed. Using the standard ILDA test pattern. Laboratory power supply at +/-15VDC,room temperature. Windows PC with Pangolin,12/30k ILDA test-frame full size. 7x11x0.6mm mirror was used during measuring period. The galvo is fixed in the standard mounts on an aluminium base plate, no forced cooling. | ||
+ | |||
+ | <br> | ||
{| | {| |
Aktuelle Version vom 1. Januar 2016, 17:13 Uhr
Budget Laser Scanner Galvo Set ILDA Closed Loop 12 Kpps from E-Bay.
E-Bay
The original informations form the seller:
- Closed Loop Moving Magnet Scanner
- Input resistance: 200K ohms, differential
- Signal Input voltage:±5V
- Input voltage requirements: +15V/1.0A,-15V/0.6A
- Operating temperature range:0~50 degrees C
- Optical angle:±30° max
- Scanner speed:>15Kpps (30K ILDA test-pattern ,±20°optical)
- Mirror dimensions WxL: 7mm*11mm*0.6mm(wide wave-length)
- Board size:7.4cm(long)*5.0cm(wide)*2.5cm(high)
The Scanner was measured by an independent source and confirmed by the factory with PANGOLIN QM2000 card. Running at the desired output speed. Using the standard ILDA test pattern. Laboratory power supply at +/-15VDC,room temperature. Windows PC with Pangolin,12/30k ILDA test-frame full size. 7x11x0.6mm mirror was used during measuring period. The galvo is fixed in the standard mounts on an aluminium base plate, no forced cooling.
Deflection angle | Operating voltage | Speed@ Mirrors size |
---|---|---|
20º | ±15V | 10Kpps @ 7*11*0.6 |
15º | ±15V | 15Kpps @ 7*11*0.6 |
5º | ±15V | 25Kpps @ 7*11*0.6 |